-40%

Newport 202A-JF1 Thermocouple Meter -216F To +1400F 115Vac ~NEW~

$ 147.83

Availability: 100 in stock
  • Return shipping will be paid by: Seller
  • Brand: Newport
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Restocking Fee: No
  • Condition: 100% new product. Box show some minor shelf wear.
  • MPN: 202A-JF1
  • Item must be returned within: 30 Days

    Description

    Newport 202A-JF1 Thermocouple Meter -216F To +1400F 115Vac ~NEW~.
    Models 202A-J
    ,
    -K
    and
    -T
    are 3 1/2 digit ±1,999 count) panel meters for thermocouple types J, K and T. They are available for display in °C or °F and resolution of 1° up to 1,999° or 0.1° up to 199.9°. They are recommended for demanding indication-only applications where exceptionally low-cost is required. For display up to 1,999.9° with 0.1° resolution, Newport recommends its 2002B Series meters, which provides a 4 1/2 digit (±19,999 count) main assembly.
    SPECIFICATIONS
    INPUT
    Thermocouple:
    Type J (Iron-Constantan, Fe-CuNi)
    Type K (Chromel-Alumel, NiCr-NiAl)
    Type T (Copper-Constantan, Cu-CuNi)
    Calibration:
    IEC 584-1 (IPTS-68)
    Configuration:
    Single-ended (-TC lead connected to ANA GND)
    Polarity:
    Bipolar
    Zero:
    Adjustable ±20°C (±36°F)
    Cold-junction tempco:
    ±0.05 deg/deg
    Sensor-wire resistance effect per conductor:
    Type J:
    40 µdeg/deg/ohm, up to 2500 ohm
    Type K:
    50 µdeg/deg/ohm, up to 2000 ohm
    Type T:
    50 µdeg/deg/ohm, up to 2000 ohm
    Sensor-break current:
    300 nA
    Sensor-break indication:
    Meter displays positive overrange (upscale)
    NOISE REJECTION
    NMR, SIG HI to SIG LO:
    70 dB, 50/60 Hz
    CMR, ANA GND to PWR GND:
    120 dB, DC to 60 Hz
    CMV, ANA GND to PWR GND:
    1500 Vp per HV test, 354 Vp per IEC spacing
    ACCURACY AT 25°C (1° resolution models)
    Range for rated accuracy:
    Type J:
    -138 to 760°C (-216 to 1400°F)
    Type K:
    -105 to 1248°C (-157 to 1999°F)
    Type T:
    -112 to 400 °C (-170 to 752°F)
    Maximum error:
    ±1.5°C (±2.7°F) ±1/2 count
    Span tempco:
    ±0.01% of reading/°C
    Resolution:
    0.1°C or 0.1°F (jumper-selectable)
    Full-scale step response:
    1 s
    Warmup to rated accuracy:
    10 min
    ACCURACY AT 25°C (0.1° resolution models)
    Range for rated accuracy, all T/C types:
    -105.0 to 199.9°C (-157.0 to 199.9°F)
    Maximum error:
    ±1.0°C (±1.8°F) ±1/2 count
    Span tempco:
    ±0.01% of reading/°C
    Resolution:
    0.1°C or 0.1°F (jumper-selectable)
    Full-scale step response:
    1 s
    Warmup to rated accuracy:
    20 min
    ANALOG OUTPUT (linearized)
    Voltage:
    1 mV/count
    Calibration error:
    ±1.5 mV on °C, ±2.7 mV on °F
    Current:
    1 mA max
    Source resistance:
    68 ohm
    ANALOG-TO-DIGITAL CONVERSION
    Technique:
    Dual-slope, average value
    Signal-integration period:
    100 ms
    Read rate:
    2.5/s
    DISPLAY
    Type:
    7-segment, red LED
    Height:
    0.56 in (14.2 mm)
    Symbols:
    -1.8.8.8
    Overrange indication:
    Three least-significant digits blank
    DIGITAL INPUTS
    Level:
    TTL or 5 V CMOS compatible
    POWER
    AC voltages:
    115 or 230 V ac, ±15%
    AC frequency:
    49-440 Hz
    DC voltages:
    9-32 V dc, isolated to 300 Vp; 26-56 V dc, isolated to 300 Vp
    Power consumption:
    3.7 W
    Output voltages:
    +4.7 V dc and -4.7 V dc ±5%, 10 mA max
    ENVIRONMENTAL
    Operating temperature:
    0 to 60°C
    Storage temperature:
    -40 to +85°C
    Relative humidity:
    95% at 40°C (non-condensing)