AIR DOOR CLOSER DC110 MERONI WITH VARIABLE FORCEDOOR CLOSING SPRING AND COMPASS ARM FLEXIBLE AND CERTIFIED EN 1634
-
Door closer tested for fire and smoke doors according to EN 1634.
- Assembly on both RIGHT and LEFT opening doors.
- The door closer spring can be combined with both
arms with or without locking system (with or without stop).
- Door closer for doors of
maximum width 1100 mm.
-
Maximum door weight: 80 Kg.
- Possibility of adjusting the strength of the door closer (
EN 2-3-4
), closing speed and final stroke adjustment.
AIR DOOR CLOSER DC110 MERONI - TECHNICAL SPECIFICATIONS
FORCE EN2
- Maximum door width: 850 mm.
- Maximum door weight: 25-45 kg.
FORCE EN3
- Maximum door width: 950 mm.
- Maximum door weight: 45-60 kg.
FORCE EN4
- Maximum door width: 1100 mm.
- Maximum door weight: 60-80 kg.
-
Closing speed and final stroke door closer DC110 adjustable by 2 independent valves.
- Closing speed action angle: 180 ° - 10 °
- Final shot speed action angle: 10 ° - 0 °
AIR DOOR CLOSER DC110 MERONI - INSTALLATIONS
DOOR CLOSER ASSEMBLY ON BOTH RIGHT AND LEFT DOORS
The DC110 overhead door closer can be installed on both door opening directions following the instructions and drilling templates shown in the catalog below.
It is also possible to apply the door closer both on the hinged side and on the opposite side
, respectively by mounting the door closer spring on the door frame or frame.
>> DOOR CLOSER CATALOG DC110 - MOTAGE DIAGRAMS <<
AIR DOOR CLOSER DC110 MERONI - EQUIPMENT
-
Door closer spring DC110 in the chosen finish.
-
Door closer arm DC110 with or without stop (WITH STOP or STANDARD) of the chosen finish.
-
Fastening screws for wood and metal.
-
Assembly diagrams and instructions.
DOOR CLOSING SPRING AND COMPASS ARM FLEXIBLE AND CERTIFIED EN 1634 - Door closer tested for fire and smoke doors according to EN 1634. - The door closer spring can be combined with both arms with or without locking system (with or without stop). - Possibility of adjusting the strength of the door closer (EN 2-3-4), closing speed and final stroke adjustment. - Closing speed and final stroke door closer DC110 adjustable by 2 independent valves. The DC110 overhead door closer can be installed on both door opening directions following the instructions and drilling templates shown in the catalog below. It is also possible to apply the door closer both on the hinged side and on the opposite side, respectively by mounting the door closer spring on the door frame or frame. - Door closer arm DC110