    Description

    STORE HOME
    ALL ITEMS
    HOT ITEMS
    ABOUT US
    ADD TO FAVS
    FEEDBACK
    CONTACT US
    DC14-600V 20-50-100A LCD Digital Voltmeter Ammeter Volt AmpPower Kwh Panel Meter
    DC 14-600V 20-50-100A LCD Digital Voltmeter Ammeter Volt Amp Power Kwh Panel Meter
    A.Function and characteristics:
    1.measurement and screen display : full-view colorful LCD screen,display the DC current, voltage, active power and electric energy at the same time.
    2.The value of electric energy will be saved real time, when the meter power off and restart, the value of electric energy will not be lost, the meter will continue to the cumulative.
    3.When you press the button on the meter, the value of elecric energy will be set zero.
    4.The meauring voltage will supply power for the meter, so it is not need any other power .
    B.Measurement range
    D69-3062
    DC voltage: 14-600v, display format: 14-600.0 when voltage < 100V display format: 14.00-99.99, when voltage > 100V, display format 100.0-600.0
    DC current: 0-20A, display format 0.00-20.00
    DC active power: 0-12000W when active power < 10000W, display format 0.0-9999.9,
    when active power > 10000, display power 10000-12000
    DC electric energy: 0.0-9999 999kwh
    when electric energy< 10000kwh, display format 9999.999kwh
    when 10000kwh < electric energy < 100000kwh, display format 99999.99kwh
    when 100000kwh < electric energy < 1000000kwh, display format 999999.9kwh,
    when 1000000kwh < electric energy < 10000000kwh, display format 9999999kwh
    D69-3065
    DC voltage: 14-600V, when voltage < 100V display format: 14.00-99.99, when voltage > 100V, display format 100.0-600.0
    DC current: 0-50.00A, display format:0.00-50.00 (Client should buy a DC current shunt 100/75mV)
    DC active power: 0-30000W when active power < 10000W, display format 0.0-9999.9,
    when active power > 10000, display power 10000-30000
    DC electric energy: 0.0-9999 999kwh
    when electric energy< 10000kwh, display format 9999.999kwh
    when 10000kwh < electric energy < 100000kwh, display format 99999.99kwh
    when 100000kwh < electric energy < 1000000kwh, display format 999999.9kwh,
    when 1000000kwh < electric energy < 10000000kwh, display format 9999999kwh
    D69-3061
    DC voltage: 14-600V, when voltage < 100V display format: 14.00-99.99, when voltage > 100V, display format 100.0-600.0
    DC current: 0-100.0A, when current < 100A display format:0.00-99.99, when current > 100A, display format 100.0
    (Client should buy a DC current shunt 100/75mV)
    DC active power: 0-60000W when active power < 10000W, display format 0.0-9999.9,
    when active power > 10000, display power 10000-60000
    DC electric energy: 0.0-9999 999kwh
    when electric energy< 10000kwh, display format 9999.999kwh
    when 10000kwh < electric energy < 100000kwh, display format 99999.99kwh
    when 100000kwh < electric energy < 1000000kwh, display format 999999.9kwh,
    when 1000000kwh < electric energy < 10000000kwh, display format 9999999kwh
    C.Specification Parameter1.working voltage: 14.00-600VDC
    2.measuring voltage:14.00-600.0VDC
    3.measuring current: 0-20.00A
    0-50A (The client should buy a DC current shunt 50/75mV)
    0-100A (The client should buy a DC current shunt 100/75mV)
    4.measuring active power: 0-12000W/5.0-30000W/0-60000W
    5.measuring accuracy: 1%
    D.Attention:
    The meter should use in the indoor, do not use outside door.
    When measuring voltage or current exceeds the rating, the meter will be destroy.
    You should connect the wire follow the wiring diagram indicate, the meter will destroy with wrong wire connecting.
    DC current shunt must connect fllow the wiring diagram to the negative of the "mesuring/working voltage",the meter will destroy with wrong wire connecting.
    E.Connecting
    D69-3062
    Follow the wiring diagram on the right.
    connect the negative of the payload to the terminal of 1, and the positive of the payload to the terminal of 4.
    connect the negative of the measuring voltage to the terminal of 2, and the positive of the measuring current to the terminal of 3.
    D69-3065&D69-3061
    The negative of "mesuring/working voltage" should not connect to the terminal of 3, you must first connect to the DC current shunt, then connect to the terminal of 3 (You must follow the wiring diagram)
    If you only meaure the voltage, the DC current shunt and the payload is not necessary,you can only connect the positive of "meauring/working voltage" to the terminal of 4 and the negative to the terminal of 3.
    F.Size and Installation Size:
    Size: 79×43×48
    Installation size : 76×39
    SKU#: XB.FG.414 net:2.9oz Shipping Weight:3oz
    XB.FG.415 + XB.FG.417 net:5.32oz Shipping Weight:6oz
    XB.FG.416 + XB.FG.418 net:7.3oz Shipping Weight:8oz
    6-FR Envelope;5-Padded;6-BoxA;12-BoxM
    Payment
    Payment:
    Paypal Preferred.
    Local pickup NOT available at this time.
    Shipping
    Shipping:
    We process your order within 1 business day upon payment(note: NOT counting holidays or weekends).
    International shipping also available, please note by default all international packages does not come with tracking unless upgraded to priority mail.
    Package transit time: please expect 3-7 business days within US, 10-20 business days to Canada, up to 25 business days all around the world.
    RETURN & REFUND
    Return & Refund:
    Please read the item description and check the pictures carefully before bidding. Return or refund is available only if item DOA or there's error in item description causing the item not fitting your need. In such cases, seller pays for all related shipping cost if any.
    Returns are also acceptable if buyer purchased this by mistake and item still in good condition for reselling. Buyer is responsible for all related shipping cost.
    FeedbackWe maintain high standards of excellenceandstrive for 100% customer satisfaction!Feedback is very important to us. We request that you contact us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.
    ABOUT US
    High Quality
    ETL/CSA/CE/NSF/FCC - We passed every evaluation of pool products, even ASTM which for pool alarm in USA laboratory..
    Customer - Service
    We value the service we provide and our loyal returning customers can always expect some appreciation from us, like a future service, discount or a gift.
    Affordable Prices
    We aim to make our service as reasonably priced as possible. That's why we cut on all unessential business expenses...
    STORE HOME
    ALL ITEMS
    HOT ITEMS
    ABOUT US
    ADD TO FAVS
    FEEDBACK
    CONTACT US
    Copyright © 2017 wfyb. All Rights Reserved.