    AC90~260V Din Rail Thermostat 2 Way Relay Output Temperature Alarm Controller
    -40~110℃ Din Thermostat with sensor High/Low Temperature 2 Alarm Relay NO NC COMMON Output 7A/250VAC AC90~260V
    Features:
    -Strong anti-interference ability, stable performance, simple circuit and high precision; the outer shell adopts a guide rail casing, which is easy to install and beautiful in appearance.
    -And has the function of adjustment and digital filtering,
    -Standard 2 relay output function, contact capacity 7A/250VAC.
    Specifications:
    Power supply: working voltage AC90~260V; power consumption is less than 2W (other power supplies can be customized)
    Measuring accuracy: 0.5%FS±1 Measuring range -40~110℃
    Display character height: 0.36 inches high brightness red LED (other colors can be customized)
    Use environment: -10~60℃ (relative humidity below 80%)
    Dimensions: 110*36 *60 (mm)
    Sensor Length: 1.5m
    Package included:
    1* Din Rail Thermostat
    1* Sensor
    -------
    Code Table:
    TY1: Relay 1 output alarm type
    0: Upper limit alarm, temperature ≥ AL1, the relay is closed, ≤ (AL1-HY1), the relay is off.
    1: Lower limit alarm, temperature ≤ AL1, the relay is closed, ≥ (AL1+HY1), the relay is off.
    2: Upper and lower limit alarm. Temperature ≥ AL1, the relay is closed, ≤ HY1, the relay is closed.
    AL1: Relay 1 action value
    -40.0~130.0
    HY1: Relay 1 return difference
    -40.0~130.0
    TY2: Relay 2 output alarm type
    0: Upper limit alarm, temperature ≥ AL2, the relay is closed, ≤ (AL2-HY2), the relay is off.
    1: Lower limit alarm, temperature ≤ AL2, the relay is closed, ≥ (AL2+HY2), the relay is off.
    2: Upper and lower limit alarm. Temperature ≥ AL2, the relay is closed, ≤ HY2, the relay is closed.
    AL2: Relay 2 action value
    -40.0~130.0
    HY2: Relay 2 return difference
    -40.0~130.0
    SEC: Relay action delay value
    0-999 seconds
    When the relay AL1 or AL2 reaches the operating conditions, it will delay the action for SEC seconds. When it is 0, there is no delay.
    LC: Temperature deviation correction value
    -20.0~20.0 (display value = measurement value + LC)